The CT601 Serial to IP Converter is used to connect a TekCARE®
NC300/II nurse call system or a monitored foreign
system to a facility’s LAN. Events and messages from the
connected system are sent across the LAN to either an
NC385 Tek-MMARS®300 or a Tek-BRIDGE™ running TekALERT™
Software.
The CT601 Serial to IP Converter becomes a virtual COM port on the Tek-MMARS®300 or Tek-BRIDGE™, and provides long distance communication between it and the monitored serial device.
The CT601 eliminates the otherwise expensive long-distance cabling required for these connections. Configuring the CT601 is accomplished using software provided with the device. The unit can be wall or DIN-rail mounted. The CT601 incorporates surge protection.
Specifications
Serial Port: Male DB9 serial port, 1200 bps to 115 Kbps, hardware flow control
RS232 Signals: Rx, Tx, RTS, CTS, DTR, DSR, GND, DCD
Network Port: 10Base-T Ethernet
Protocols: ARP, IP/ICMP, TCP/IP, Telnet, DHCP client, DNS
Security: User ID & Password, IP Address filtering
Power: 7.5 ~ 15VDC, 300mA 7.5V
Environment: 90% non-condensing humidity; 0˚C ~ 50˚C operating temperature.
Dimensions: 3.9″×2.8″×1.0″ (100mm×72mm×25mm)
Certification: FCC (A), CE, MIC
CT601 Serial to IP Converter
Required Components One of the following:
• NC385 Tek-MMARS®300 Management Monitoring and Reporting System
• NC470 Tek-BRIDGE™ with Tek-CARE®400 Software
• NC501ES Tek-BRIDGE™ with Tek-CARE®500 Software
• NC601 Tek-BRIDGE™ with Tek-ALERT™ Software
Plus one for each monitored system:
• LS302 Tek-CARE® NC300/II Connection License –or– • LS601 Tek-ALERT™ Software License>
The CT601 Serial to IP Converter becomes a virtual COM port on the Tek-MMARS®300 or Tek-BRIDGE™, and provides long distance communication between it and the monitored serial device.
The CT601 eliminates the otherwise expensive long-distance cabling required for these connections. Configuring the CT601 is accomplished using software provided with the device. The unit can be wall or DIN-rail mounted. The CT601 incorporates surge protection.
Specifications
Serial Port: Male DB9 serial port, 1200 bps to 115 Kbps, hardware flow control
RS232 Signals: Rx, Tx, RTS, CTS, DTR, DSR, GND, DCD
Network Port: 10Base-T Ethernet
Protocols: ARP, IP/ICMP, TCP/IP, Telnet, DHCP client, DNS
Security: User ID & Password, IP Address filtering
Power: 7.5 ~ 15VDC, 300mA 7.5V
Environment: 90% non-condensing humidity; 0˚C ~ 50˚C operating temperature.
Dimensions: 3.9″×2.8″×1.0″ (100mm×72mm×25mm)
Certification: FCC (A), CE, MIC
CT601 Serial to IP Converter
Required Components One of the following:
• NC385 Tek-MMARS®300 Management Monitoring and Reporting System
• NC470 Tek-BRIDGE™ with Tek-CARE®400 Software
• NC501ES Tek-BRIDGE™ with Tek-CARE®500 Software
• NC601 Tek-BRIDGE™ with Tek-ALERT™ Software
Plus one for each monitored system:
• LS302 Tek-CARE® NC300/II Connection License –or– • LS601 Tek-ALERT™ Software License>
Description The CT601 Serial to IP Converter is used to connect a TekCARE® NC300/II nurse call system or a monitored foreign system to a facility’s LAN. Events and messages from the connected system are sent across the LAN to either an NC385 Tek-MMARS®300 or a Tek-BRIDGE™ running TekALERT™ Software. The CT601 Serial to IP Converter becomes a virtual COM port on the Tek-MMARS®300 or Tek-BRIDGE™, and provides long distance communication between it and the monitored serial device. The CT601 eliminates the otherwise expensive long-distance cabling required for these connections. Configuring the CT601 is accomplished using software provided with the device. The unit can be wall or DIN-rail mounted. The CT601 incorporates surge protection. Specifications Serial Port: Male DB9 serial port, 1200 bps to 115 Kbps, hardware flow control RS232 Signals: Rx, Tx, RTS, CTS, DTR, DSR, GND, DCD Network Port: 10Base-T Ethernet Protocols: ARP, IP/ICMP, TCP/IP, Telnet, DHCP client, DNS Security: User ID & Password, IP Address filtering Power: 7.5 ~ 15VDC, 300mA 7.5V Environment: 90% non-condensing humidity; 0˚C ~ 50˚C operating temperature. Dimensions: 3.9″×2.8″×1.0″ (100mm×72mm×25mm) Certification: FCC (A), CE, MIC CT601 Serial to IP Converter Required Components One of the following: • NC385 Tek-MMARS®300 Management Monitoring and Reporting System • NC470 Tek-BRIDGE™ with Tek-CARE®400 Software • NC501ES Tek-BRIDGE™ with Tek-CARE®500 Software • NC601 Tek-BRIDGE™ with Tek-ALERT™ Software Plus one for each monitored system: • LS302 Tek-CARE® NC300/II Connection License –or– • LS601 Tek-ALERT™ Software License
Products Ship From Chicago, IL and Aurora, CO